| HP part number |
ProCurve Switch 2650 (J4899C) |
ProCurve Switch 2650-PWR (J8165A) |
ProCurve Switch 2626 (J4900C) |
| Ports |
48 auto-sensing 10/100 ports (IEEE 802.3 Type 10Base-T, IEEE 802.3u Type 100Base-TX)
Media Type: Auto-MDIX
Duplex: half or full
1 RS-232C DB-9 console port
2 dual-personality ports
each port can be used as either an RJ-45 10/100/1000 port (IEEE 802.3 Type 10Base-T; IEEE 802.3u Type 100Base-TX; IEEE 802.3ab 1000Base-T Gigabit Ethernet) or an open mini-GBIC slot (for use with mini-GBIC transceivers)
|
48 auto-sensing 10/100 ports (IEEE 802.3 Type 10Base-T, IEEE 802.3u Type 100Base-TX)
Media Type: Auto-MDIX
Duplex: half or full
1 RS-232C DB-9 console port
2 dual-personality ports
each port can be used as either an RJ-45 10/100/1000 port (IEEE 802.3 Type 10Base-T; IEEE 802.3u Type 100Base-TX; IEEE 802.3ab 1000Base-T Gigabit Ethernet) or an open mini-GBIC slot (for use with mini-GBIC transceivers)
|
24 auto-sensing 10/100 ports (IEEE 802.3 Type 10Base-T, IEEE 802.3u Type 100Base-TX)
Media Type: Auto-MDIX
Duplex: half or full
1 RS-232C DB-9 console port
2 dual-personality ports
each port can be used as either an RJ-45 10/100/1000 port (IEEE 802.3 Type 10Base-T; IEEE 802.3u Type 100Base-TX; IEEE 802.3ab 1000Base-T Gigabit Ethernet) or an open mini-GBIC slot (for use with mini-GBIC transceivers)
|
| Physical characteristics |
|
|
|
| Dimensions |
12.8(d) x 17.32(w) x 1.75(h) in. (32.51 x 43.99 x 4.45 cm) (1U height) |
18.03(d) x 17.42(w) x 1.75(h) in. (45.8 x 44.25 x 4.45 cm) (1U height) |
12.8(d) x 17.32(w) x 1.73(h) in. (32.51 x 43.99 x 4.39 cm) (1U height) |
| Weight |
9.78 lb. (4.44 kg), Fully loaded |
16.31 lb. (7.4 kg), Fully loaded |
9.15 lb. (4.15 kg), Fully loaded |
| Memory and processor |
|
|
|
| Processor |
Motorola PowerPC MPC8245 @ 266 MHz, 8 MB flash, 32 MB SDRAM |
Motorola PowerPC MPC8245 @ 266 MHz, 8 MB flash, 32 MB SDRAM |
Motorola PowerPC MPC8245 @ 266 MHz, 8 MB flash, 32 MB SDRAM |
| Mounting |
|
|
|
| |
Mounts in an EIA-standard 19 in. telco rack or equipment cabinet (hardware included); horizontal surface mounting only
|
Mounts in an EIA-standard 19 in. telco rack or equipment cabinet (hardware included); horizontal surface mounting only
|
Mounts in an EIA-standard 19 in. telco rack or equipment cabinet (hardware included); horizontal surface mounting only
|
| Performance |
|
|
|
| Latency |
< 13.3 s (LIFO) |
< 12 s (LIFO) |
< 13.3 s (LIFO) |
| Throughput |
up to 10.1 million pps |
up to 10.1 million pps |
up to 6.6 million pps |
| Routing/Switching capacity |
13.6 Gbps |
13.6 Gbps |
9.6 Gbps |
| MAC address table size |
8000 entries |
8000 entries |
8000 entries |
| Environment |
|
|
|
| Operating temperature |
32F to 131F (0C to 55C) |
32F to 122F (0C to 50C) |
32F to 122F (0C to 50C) |
| Operating relative humidity |
15% to 95% @ 104F (40C), non-condensing |
15% to 95% @ 104F (40C), non-condensing |
15% to 95% @ 104F (40C), non-condensing |
| Non-operating/Storage temperature |
-40F to 158F (-40C to 70C) |
-40F to 158F (-40C to 70C) |
-40F to 158F (-40C to 70C) |
| Non-operating/Storage relative humidity |
15% to 95% @ 149F (65C), non-condensing |
15% to 95% @ 149F (65C), non-condensing |
15% to 95% @ 149F (65C), non-condensing |
| Altitude |
up to 15000 ft. (4.6 km) |
up to 15000 ft. (4.6 km) |
up to 15000 ft. (4.6 km) |
| Acoustic |
Power: 50 dB; DIN 45635T.19 per ISO 7779 |
Power: 53 dB; DIN 45635T.19 per ISO 7779 |
Power: 50 dB; DIN 45635T.19 per ISO 7779 |
| Electrical characteristics |
|
|
|
| Maximum heat dissipation |
342 BTU/hr (360.81 kJ/hr) |
2155 BTU/hr (2273.53 kJ/hr) |
342 BTU/hr (360.81 kJ/hr) |
| Voltage |
100-240 VAC |
100-240 VAC |
100-240 VAC |
| Current |
1.5 A |
7.5 / 3.5 A |
1.5 A |
| Power consumption |
100 W |
631 W |
100 W |
| Frequency |
50 / 60 Hz |
50 / 60 Hz |
50 / 60 Hz |
| Safety |
|
|
|
| |
CSA 22.2 No. 950 cUL (CSA 950) EN 60950/IEC 60950 NOM-019-SCFI-1994 UL 1950 3rd edition UL 60950
|
CSA 22.2 No. 950 cUL (CSA 950) EN 60950/IEC 60950 NOM-019-SCFI-1994 UL 1950 3rd edition UL 60950
|
CSA 22.2 No. 950 cUL (CSA 950) EN 60950/IEC 60950 NOM-019-SCFI-1994 UL 1950 3rd edition UL 60950 |