PowerGuard Extreme Home Theatre Protector PGXH3708 is a combination of the PowerGuard Original, Continuous Power Filter and Ultra Filter. The protection strategy is arranged with the PowerGuard Original patented Active Intelligent Sensing front ending the whole of the PGXH protection to the supply voltage input, protecting all eight outlets and is then linked in conjunction with Cascade Multi-stage Filtering on the AC Mains.
The Primary bank of six outlets is CPF filtered with additional crossover filtering to the Isolated Dual Outlet bank, arranged in a Cascade configuration. The Isolated Dual Outlet bank is totally isolated from the Primary bank and final filtered.
The AC filter is a similar specification as the Continuous Power Filter for clamping and energy dissipation, but is arranged in a cascade, multi-stage circuit design the benefit is that rather than totally block all the excess energy and risk causing a back EMF, that could damage neighbouring unprotected equipment, the protection is designed to capture, absorb and dissipate the excess energy or transient interference. Residual interference is captured by each successive stage; the cascade circuit design captures any graduated overflow at each successive stage of the filter providing cleaner power.
PowerGuard Extreme Home Theatre Protector antenna splitter provides greater protection by design. Low pass arresters work to protect by diverting potentially damaging induced voltages to a direct connected earth..
FEATURES
- More than double the AC Mains protection of conventional multi outlet boards
- Cascade Multi Stage Filtering, diverts for:
Spike Protection
RFI and EMI Filtration
- Patented Active Intelligent Sensing, isolates for:
True AC Mains Over Voltage, Surge and Phase Loss Protection
Under Voltage, Brown Out (Sag) Protection
- Antenna Splitter (Buffer Pre Amplifier Protected)
The BPA circuit electrically separates the input from the output, the dual co-axial outputs are well protected with minimal signal degradation.
Low pass arresters front end the BPA, and work to protect by diverting potentially damaging induced voltages to a direct connected earth
SPECIFICATION - AC ELECTRICAL - SPIKE ARRESTING & FILTRATION
Electrical Rating 110~230/240V AC 50/60Hz 10 Amps (2400w)
|
Clamping Voltage
|
275V
|
Protection Modes
|
Differential Mode (Active-Neutral)
|
Maximum Amps Absorption
|
55,000 Amps
|
|
Common Mode (Active-Neutral Earth)
|
Maximum Joules Absorption
|
1,500 Joules
|
Reaction Time
|
1 to 3 n/Seconds
|
Operation Temperature
|
-10 to 70C
|
SPECIFICATION - AC ELECTRICAL - OVER/UNDER VOLTAGE