| Model | 
          OL1000ERTXL2U | 
        
        
          | Capacity(VA/W) | 
          1000VA / 900W | 
        
        
          | Typology | 
          Online (Double Conversion) | 
        
        
          | Form Factor | 
          Rackmount / Tower (Convertible) | 
        
        
          | Energy-Saving Technology | 
          Yes, ECO Mode Efficiency 93% | 
        
        
          | Input  | 
        
        
          | Voltage Range | 
          120~139Vac for 0~25% Load 140~159Vac for 0~50% Load 160~179Vac for 0~75% Load 180~280Vac for 0~100% Load
  | 
        
        
          | Frequency Range | 
          40~70Hz | 
        
        
          | Input Plug Type | 
          IEC C14 | 
        
        
          | Output  | 
        
        
          | Voltage Range | 
          Pure Sinewave at 200, 208, 220, 230, 240Vac (Configurable) 2%  | 
        
        
          | Frequency Range | 
          50 / 60Hz (Auto-Sensing or Configurable) 0.25Hz  | 
        
        
          | Transfer Time (Typical) | 
          0ms | 
        
        
          | Overload Protection | 
          Line Mode 105~125% Load for 1 min, 126~150% Load for 10 sec Battery Mode 105~130% Load for 10 sec, 131~150% Load for 2 sec | 
        
        
          | Short Circuit Protection | 
          UPS Output Cut Off Immediately  | 
        
        
          | Surge Protection and Filtering | 
        
        
          | Lightning / Surge Protection | 
          Yes | 
        
        
          | DSL/Phone/Fax/Modem protection | 
          RJ11/RJ45(One In/One Out) | 
        
        
          | Physical | 
        
        
          | Receptacles | 
          (8) IEC C13 | 
        
        
          | Dimensions(H x W x D)(mm) | 
          88x433x430 | 
        
        
          | Weight(kg) | 
          18 | 
        
        
          | Battery | 
        
        
          | Sealed Maintenance Free Lead Acid Battery | 
          12V / 9AH x 3 | 
        
        
          | Hot-Swappable | 
          Yes | 
        
        
          | Typical Recharge Time | 
          4 Hours | 
        
        
          | Runtimes | 
        
        
          | Half load / Full load (mins) | 
          10/6 | 
        
        
          | Status Indication | 
        
        
          | Indicators | 
          Power On, Line Mode, Battery Mode, Bypass Mode, Fault, Replace Battery | 
        
        
          | Audible Alarms | 
          Battery Mode, Battery Low, Overload, UPS Fault, Replace Battery | 
        
        
          | Multi-Function LCD Readout | 
          Yes | 
        
        
          | Communication | 
        
        
          | Power Management Software | 
          PowerPanel Business Edition | 
        
        
          | Management | 
        
        
          | Self-Test | 
          Yes | 
        
        
          | Auto-Charge/Auto-Restart | 
          Yes | 
        
        
          | Auto-Overload Recovery | 
          Yes | 
        
        
          | Cold Start(DC Start) | 
          Yes | 
        
        
          | COM Interface | 
          (1) Serial Port (RS232), (1) USB Port, (1) Relay Out, (1) EPO | 
        
        
          | SNMP/HTTP Capable | 
          Optional |