OVERVIEW |
|
UPC
Code |
037332123473 |
UPS
Type |
Line-Interactive |
INPUT |
|
Rated
input current (Maximum Load) |
10A |
Nominal
Input Voltage(s) Supported |
230V
AC |
UPS
Input Connection Type |
C14
inlet |
UPS
Input Connection Description |
Attached
15cm line cord with C14 inlet. The C14 inlet accepts user-supplied AC
power cord with country specific plug |
UPS
Input Cord Length (ft.) |
0.5 |
UPS
Input Cord Length (m) |
0.2 |
Input
Phase |
Single-Phase |
OUTPUT |
|
Output
Volt Amp Capacity (VA) |
550 |
Output
Watt Capacity (Watts) |
300 |
Nominal
Voltage Details |
230V
nominal output in battery mode |
Frequency
Compatibility |
50
/ 60 Hz |
Frequency
Compatibility Details |
Automatic
frequency selection |
Output
Voltage Regulation (Line Mode) |
+8%,
-21% |
Output
Voltage Regulation (Battery Mode) |
+/-
5% |
Included
Output Power Cables |
Includes
2 C13 to C14 output power cables |
UPS
Output Receptacles (Surge Suppression Only) |
3
UPS outlets, 3 surge-only outlets |
Hot-Swap
PDU options |
PDUBHV10
(2U / 8 C13 outlets) |
Output
AC Waveform (AC Mode) |
Sine
wave |
Output
AC Waveform (Battery Mode) |
PWM
sine wave |
Nominal
Output Voltage(s) Supported |
220V;
230V; 240V |
Output
Receptacles |
(6)
C13 |
Individually
Controllable Load Banks |
No |
BATTERY |
|
Battery
Type |
Valve
Regulated Lead Acid (VRLA) |
Half
Load Runtime (min.) |
5.1
min. (150w) |
Expandable
Runtime |
No |
DC
System Voltage (VDC) |
12 |
Battery
Access |
Battery
access door |
Internal
UPS Replacement Battery Cartridge |
IMPORTANT
BATTERY REPLACEMENT INFORMATION > If the original battery inside your
AVRX550U UPS has a rating of 12V 3.6AH, please order Tripp Lite
RBC36H (quantity 1) replacement battery; If the original
battery inside your AVRX550U UPS has a rating of 12V 5AH, please contact
Tripp Lite for assistance |
Battery
Replacement Description |
Hot-swappable,
user replaceable batteries |
VOLTAGE
REGULATION |
|
Voltage
Regulation Description |
Automatic
voltage regulation (AVR) maintains line power operation with an input
voltage range of 159 to 282VAC |
Overvoltage
Correction |
Input
voltages between 245 and 282 are reduced by
12% |
Undervoltage
Correction |
Input
voltages between 159 and 205 are boosted by
14% |
USER
INTERFACE, ALERTS & CONTROLS |
|
Switches |
Combination
switch controls on/off power status and self-test
operation |
Audible
Alarm |
Audible
alarm indicates power-failure and overload
status |
LED
Indicators |
2
LEDs indicate power status and overload/check battery
status |
SURGE
/ NOISE SUPPRESSION |
|
UPS
AC Suppression Joule Rating |
320 |
UPS
AC Suppression Response Time |
Instantaneous |
UPS
Dataline Suppression |
1
line TEL/DSL (1 in / 1 out) |
EMI
/ RFI AC Noise Suppression |
Yes |
PHYSICAL |
|
Primary
Form Factor |
Desktop |
Installation
Form Factors Supported with Included Accessories |
Tower;
Ultra-compact desktop; Wallmount |
Primary
UPS Depth (mm) |
147 |
Primary
UPS Height (mm) |
89 |
Primary
UPS Width (mm) |
279 |
Shipping
Dimensions (hwd / cm) |
11.68
x 34.04 x 22.35 |
Shipping
Weight (kg) |
4.63 |
UPS
Housing Material |
ABS |
UPS
Power Module Dimensions (hwd, cm) |
8.89
x 27.94 x 14.73 |
UPS
Power Module Weight (kg) |
3.86 |
ENVIRONMENTAL |
|
Operating
Temperature Range |
+32
to +104 degrees Fahrenheit / 0 to +40 degrees
Celsius |
Storage
Temperature Range |
+5
to +122 degrees Fahrenheit / -15 to +50 degrees
Celsius |
Relative
Humidity |
0
to 95%, non-condensing |
AC
Mode BTU / Hr. (Full Load) |
54 |
AC
Mode Efficiency Rating (100% Load) |
95% |
COMMUNICATIONS |
|
PowerAlert
Software |
For
local monitoring via the UPSs built-in communication ports, download
PowerAlert Local software at
https://www.tripplite.com/poweralert |
Communications
Cable |
USB
interface cable included |
WatchDog
Compatibility |
Supports
Watchdog application, OS and hard-reboot restart options for remote
applications |
Network
UPS Tools Compatibility |
NUT
compatible. See the full list of Tripp Lite NUT compatible UPS systems at
https://www.networkupstools.org/stable-hcl.html?manufacturer=Tripp
Lite |
Network
Management Card Description |
Network
management not supported |
Communications
Interface |
USB
(HID enabled) |
LINE
/ BATTERY TRANSFER |
|
Transfer
Time |
4
milliseconds |
Low
Voltage Transfer to Battery Power (Setpoint) |
159 |
High
Voltage Transfer to Battery Power (Setpoint) |
282 |
FEATURES
& SPECIFICATIONS |
|
Grounding
Lug |
Included |
Cold
Start (Startup in Battery Mode During a Power
Failure) |
Cold-start
operation supported |
High
Availability UPS Features |
Automatic
Voltage Regulation (AVR); Hot swappable batteries; Surge/noise
protection |
Green
Energy-Saving Features |
Greater
than 95% efficiency - GREEN UPS |
STANDARDS
& COMPLIANCE |
|
UPS
Certifications |
CE;
Tested to GOST (Russia); Tested to SASO (Saudi Arabia); Meets FCC Part 15
Category B (EMI); ROHS (Restriction of Hazardous
Substances) |
Certification
Details |
EN62040 |
WARRANTY |
|
Product
Warranty Period (International) |
2-year
limited warranty |