| Number of Controller Module | 2 |
| CPU | Intel Xeon D-2142IT 8-core 1.90 GHz processor (burst up to 3.0 GHz) per controller |
| CPU Architecture | 64-bit x86 |
| Floating Point Unit | |
| Encryption Engine | (AES-NI) |
| System Memory | 64 GB RDIMM DDR4 ECC per controller |
| Maximum Memory | 1024GB (16 x 64GB) 512 GB (8 x 64GB) per controller |
| Memory Slot | 16 x R-DIMM/LR-DIMM DDR4 8 x R-DIMM/LR-DIMM DDR4 per controllerIMPORTANT: You can only use one type of dual in-line memory module (DIMM) at a time. Do not use registered DIMM (RDIMM) with load-reduction DIMM (LRDIMM) memory. |
| Flash Memory | 4GB (Dual boot OS protection) |
| Drive Bay | 16 x 3.5-inch SAS 12Gb/s, backward-compatible to SAS 6Gb/s |
| Drive Compatibility | 3.5-inch bays: 3.5-inch SAS hard disk drives 2.5-inch SAS hard disk drives 2.5-inch SAS solid state drives |
| Hot-swappable | |
| SSD Cache Acceleration Support | L1 ARC Read Cache: RAM L2 ARC Read Cache: SSD ZIL Write Cache: NVRAM (C2F) |
| Cache for Copy To Flash (C2F) | 1 per each controller (64GB M.2 SSD) |
| Gigabit Ethernet Port (RJ45) | 3 for each controller (assign one for remote management) |
| 10 Gigabit Ethernet Port | 4 x 10GbE SFP+ for each controller |
| Wake on LAN (WOL) | |
| Jumbo Frame | |
| PCIe Slot | 2 per controller Slot 1: PCIe Gen 3 x8 (CPU) Slot 2: PCIe Gen 3 x8 (CPU)Card dimensions for PCIe slot 1~Slot 2215 x 68.9 x 18.76 mm / 8.46 x 2.71 x 0.74 inches. Wider cards can be installed if the next PCIe slot will not be used. |
| USB 3.2 Gen 1 port | 2 per each controller Note: The USB ports are for engineering purpose only. No external devices such as storage drives or UPS are supported. |
| Form Factor | 3U Rackmount |
| LED Indicators | System Power LED (Green): on/off System Status (Green/ Red): in operation, system errors, low power, degraded RAID mode, memory failure, fan/power supply failure, system/disk temperature too high, storage pool reaching threshold value, system performing take-over, power supply unit unplugged LCD Status Display (Two-digit number): Status of JBOD connection |
| Buttons | Power, Reset |
| Dimensions (HxWxD) | 132 446.2 587.75 mm |
| Weight (Net) | 30.22 kg |
| Weight (Gross) | 34.92 kg |
| Operating Temperature | 0 - 40 C (32F - 104F) |
| Storage Temperature | -20 - 70C (-4F - 158F) |
| Relative Humidity | 5-95% RH non-condensing, wet bulb: 27C (80.6F) |
| Power Supply Unit | Redundant/ Hot Swap Power Vin:90~264VAC;700W |
| Power Consumption: Operating Mode, Typical | 500.87 W Tested with drives fully populated. |
| Fan | Hot-swappable fan module (60*60*38mm; 16000RPM/12v/2.8A x 3) |
| System Warning | Buzzer |
| Standard Warranty | 5 |
| Max. Number of Concurrent Connections (CIFS) - with Max. Memory | 10000 |
| Safety Standard | FCC Class A (USA only) CE Mark ( EN55022 Class A, EN55024) EN60950 BSMI VCCI CB LVD |