All stock codes associated to this product
SMC3000RMI2U, 2728474, UPAPCSMC3000RM2, 731304310112
   Smart-UPS
   
  APC Smart-UPS C 3000VA Rack mount LCD 230V
   
  SMC3000RMI2U
   
  APC Smart-UPS,2100 Watts /3000 VA,Input 230V /Output 230V, Interface Port USB, Rack Height 2 U
   
  Includes: CD with software, Documentation CD, Installation guide, Rack Mounting brackets, USB cable
   
  Product Overview
   
  
    
    
      
        
          
            High online efficiency 
            Reduces utlility costs, generates less heat.
           
         
        
          
            Green mode 
            Patent-pending operating mode that bypasses unused electrical components in good power conditions to achieve very high operating efficiency without sacrificing any protection.
           
         
        
          
            Pure sine wave output on battery 
            Simulates utility power to provide the highest degree of compatibility for active PFC (power factor corrected) servers and sensitive electronics.
           
         
        
          
            LCD Status Display 
            Provides key UPS status at a glance. Multiple status indicators with load and battery bar graphs.
           
         
        
          
            Cold-start capable 
            Provides temporary battery power when the utility power is out.
           
         
        
          
            Temperature-compensated battery charging 
            Prolongs battery life by regulating the charge voltage according to battery temperature.
           
         
       
     
     
    
      
Smart-UPS Features & Benefits
    
    
      
        
        
          
            
              
                Boost and Trim Automatic Voltage Regulation (AVR) 
                Gives higher application availability by correcting low and high voltage conditions without using the battery (not available on all models). 
               
             
            
              
                Intelligent battery management 
                Maximizes battery performance, life, and reliability through intelligent, precision charging. 
               
             
            
              
                Power conditioning 
                Protects connected loads from surges, spikes, lightning, and other power disturbances. 
               
             
            
              
                Temperature-compensated battery charging 
                Prolongs battery life by regulating the charge voltage according to battery temperature. 
               
             
            
              
                Automatic restart of loads after UPS shutdown 
                Automatically starts up the connected equipment upon the return of utility power. 
               
             
            
              
                Automatic self-test 
                Periodic battery self-test ensures early detection of a battery that needs to be replaced. 
               
             
            
              
                Disconnected battery notification 
                Warns when a battery is not available to provide backup power. 
               
             
           
         
        
        
          
            
              
                Network manageable 
                Provides remote power management of the UPS over the network. 
               
             
            
              
                Audible alarms 
                Actively let you know if the unit is on battery, if the battery is low or if there is an overload condition. 
               
             
            
              
                LED status indicators 
                Quickly understand unit and power status with visual indicators. 
               
             
            
              
                Serial connectivity 
                Provides management of the UPS via a serial port. 
               
             
            
              
                USB connectivity 
                Provides management of the UPS via a USB port (not available on all models). 
               
             
            
              
                Disconnected battery notification 
                Warns when a battery is not available to provide backup power. 
               
             
           
         
        
        
          
            
              
                User-replaceable batteries 
                Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR) 
               
             
            
              
                Hot-swappable batteries 
                Ensures clean, uninterrupted power to protected equipment while batteries are being replaced 
               
             
            
              
                Predictive failure notification 
                Provides early-warning fault analysis ensuring proactive component replacement. 
               
             
            
              
                Resettable circuit breakers 
                Enables a quick recovery from overload events. 
               
             
            
              
                Battery failure notification 
                Provides early-warning fault analysis on batteries enabling timely preventive maintenance 
               
             
           
         
        
        
          
            
              
                Adjustable voltage-transfer points 
                Maximizes useful battery life by widening the input voltage window or tightening the output voltage regulation. 
               
             
            
              
                Adjustable voltage sensitivity 
                Provides the ability to adapt the UPS for optimal performance in specific power environments or generator applications. 
               
             
           
         
        
        
          
            
              
                Safety-agency approved 
                Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment. 
                 
                
                  
                  
                    
                      
                        
                          Output Power Capacity 
                          2100Watts /3000 VA 
                         
                       
                      
                        
                          Max Configurable Power 
                          2100Watts /3000 VA 
                         
                       
                      
                        
                          Nominal Output Voltage 
                          230V 
                         
                       
                      
                        
                          Output Voltage Distortion 
                          Less than 5% 
                         
                       
                      
                        
                          Output Frequency (sync to mains) 
                          50 Hz 
                         
                       
                      
                        
                          Topology 
                          Line Interactive 
                         
                       
                      
                      
                        
                          Output Connections 
                          
                            
                              
                                
                                  | (8) IEC 320 C13  | 
                                     | 
                                
                                
                                  | (1) IEC 320 C19  | 
                                     | 
                                
                                
                                  | (2) IEC Jumpers  | 
                                    | 
                                
                              
                            
                           
                         
                       
                     
                   
                  
                  
                    
                      
                        
                          Nominal Input Voltage 
                          230V 
                         
                       
                      
                        
                          Input Frequency 
                          50/60 Hz +/- 3 Hz (auto sensing) 
                         
                       
                      
                      
                        
                          Input voltage range for main operations 
                          180 - 287V 
                         
                       
                     
                   
                  
                  
                    
                      
                        
                          Battery Type 
                          Maintenance-free sealed Lead-Acid battery with suspended electrolyte : leakproof 
                         
                       
                      
                        
                          Typical recharge time 
                          3hour(s) 
                         
                       
                      
                      
                        
                        
                          
                            
 
                              
                              Hover over the line on the graph above to view the runtime at any desired load 
                              Curve fit to measured runtime data. All measurements taken with new, fully charged batteries, at typical environmental conditions, with no electrical input and balanced resistive load (PF = 1.0) output. 
                              
                                View Enlarged Graph 
                                View Runtime Chart 
                                 
                               
                             
                           
                         
                       
                     
                   
                  
                    
                      
Communications & Management
                    
                   
                  
                    
                      
                      
                        
                          Control panel 
                          Multi-function LCD status and control console 
                         
                       
                      
                        
                          Audible Alarm 
                          Alarm when on battery : distinctive low battery alarm : configurable delays 
                         
                       
                      
                        
                          Emergency Power Off (EPO) 
                          -- 
                         
                       
                     
                   
                  
                    
                      
Surge Protection and Filtering
                    
                   
                  
                    
                      
                        
                          Surge energy rating 
                          300Joules 
                         
                       
                      
                        
                          Filtering 
                          Full time multi-pole noise filtering : 0.3% IEEE surge let-through : zero clamping response time : meets UL 1449 
                         
                       
                     
                   
                  
                  
                  
                  
                    
                      
                        
                          Operating Environment 
                          0 - 40C 
                         
                       
                      
                        
                          Operating Relative Humidity 
                          0 - 95% 
                         
                       
                      
                        
                          Operating Elevation 
                          0-3000meters 
                         
                       
                      
                        
                          Storage Temperature 
                          -15 - 45C 
                         
                       
                      
                        
                          Storage Relative Humidity 
                          0 - 95% 
                         
                       
                      
                        
                          Storage Elevation 
                          0-15000meters 
                         
                       
                      
                        
                          Audible noise at 1 meter from surface of unit 
                          42.00dBA 
                         
                       
                      
                        
                          Online Thermal Dissipation 
                          81.00BTU/hr 
                         
                       
                     
                   
                  
                  
                    
                      
                        
                          Regulatory Approvals 
                          C-tick, CE, EAC, GOST, GS Mark, IRAM, SABS, VDE 
                         
                       
                      
                        
                          Standard Warranty 
                          2 years repair or replace 
                         
                       
                     
                   
                  
                  
                    
                      
                      
                        
                          REACH 
                          REACH: Contains No SVHCs