SRT3000XLI Features 
APC Smart-UPS SRT 3000VA 230V 
  - Battery 
  failure notification
 
Provides 
early-warning fault analysis on batteries enabling timely preventive 
maintenance
Operating 
mode that by-passes unused electrical components in good power conditions to 
achieve high operating efficiency without sacrificing protection
Patent-pending 
operating mode that bypasses unused electrical components in good power 
conditions to achieve very high operating efficiency without sacrificing any 
protection.
Text 
and mimic diagrams that display modes of operation, system parameters and 
alarms.
Protects 
the initial investment in the UPS when migrating from tower to rack-mount 
environment.
Smart-UPS On-Line Features & Benefits
Availability
  - Intelligent 
  battery management
 
Maximizes 
battery performance, life, and reliability through intelligent, precision 
charging.
Allows 
additional run time to be quickly added as needed.
Ensures 
clean, uninterrupted power to protected equipment while batteries are being 
replaced
  - Automatic 
  internal bypass
 
Supplies 
utility power to the connected loads in the event of a UPS power overload or 
fault.
  - Automatic 
  restart of loads after UPS shutdown
 
Automatically 
starts up the connected equipment upon the return of utility power.
  - Temperature-compensated 
  battery charging
 
Prolongs 
battery life by regulating the charge voltage according to battery 
temperature.
Protection
Protects 
connected loads from surges, spikes, lightning, and other power 
disturbances.
Ensures 
clean, uninterrupted power to protected equipment when generator power is 
used.
  - Input 
  power factor correction
 
Minimizes 
installation costs by enabling the use of smaller generators and cabling.
Ensures 
the product has been tested and approved to work safely with the connected 
service provider equipment and within the specified environment.
  - Frequency 
  and voltage regulation
 
Gives 
higher application availability by correcting poor frequency and voltage 
conditions without using the battery.
  - Resettable 
  circuit breaker
 
Easy 
recovery from overloads; no need to replace a fuse.
Provides 
temporary battery power when the utility power is out.
Marketing Features
  - Save 
  time with easy and convenient remote accessibility.
 
Network 
manageable via serial, USB or optional Ethernet. Includes Powerchute Network 
Shutdown Software for convenient monitoring and control, safe operating system 
shutdown, and innovative energy management capabilities.
  - Avoids 
  costly power problems by keeping your IT equipment and data protected and 
  available.
 
Network 
grade power conditioning protects from damaging surges and disruptive noise. The 
double conversion architecture provides tight voltage regulation, frequency 
regulation ,and zero transfer time to battery during power events.
  - Low 
  operating and maintenance costs with proven reliability and intelligent 
  battery management.
 
Intelligent 
battery management, pioneered by APC, maximizes battery performance and life 
through intelligent, precision temperature compensated charging. Automatic self 
tests insure battery reliability and warn customers in advance of battery 
replacement. Convenient, easy to connect, hot-swappable battery modules provide 
battery replacement without powering down.
  - Peace 
  of mind that comes with full equipment compatibility and reliability of a 
  leader
 
Provides 
pure sine wave output which is recommended by server manufacturers using active 
power factor corrected (PFC) power supplies. Safety agency tested and approved 
means that you can deploy Smart-UPS with confidence that they meet or exceed the 
industrys most rigorous standards.
Serviceability
  - User-replaceable 
  batteries
 
Increases 
availability by allowing a trained user to perform upgrades and replacements of 
the batteries reducing Mean Time to Repair (MTTR)
Provides 
notification of changing utility power and UPS power conditions
  - Disconnected 
  battery notification
 
Warns 
when a battery is not available to provide backup power.
  - Predicitive 
  failure notification
 
Provides 
early-warning fault analysis ensuring proactive component replacement.
Periodic 
battery self-test ensures early detection of a battery that needs to be 
replaced.
Protection
Protects 
connected loads from surges, spikes, lightning, and other power 
disturbances.
Ensures 
the product has been tested and approved to work safely with the connected 
service provider equipment and within the specified environment.
  - Input 
  power factor correction
 
Minimizes 
installation costs by enabling the use of smaller generators and cabling.
Ensures 
clean, uninterrupted power to protected equipment when generator power is 
used.
  - Frequency 
  and voltage regulation
 
Gives 
higher application availability by correcting poor frequency and voltage 
conditions without using the battery.
  - Resettable 
  circuit breaker
 
Easy 
recovery from overloads; no need to replace a fuse.
Provides 
temporary battery power when the utility power is out.
Adaptability
Protects 
the initial investment in the UPS when migrating from tower to rack-mount 
environment.
  - Plug-and-Play 
  external batteries
 
Ensures 
clean, uninterrupted power to the loads when adding extra runtime to the 
UPS.
  - Flash 
  upgradeable firmware
 
Install 
maintenance releases of firmware remotely using FTP.
Serviceability
Periodic 
battery self-test ensures early detection of a battery that needs to be 
replaced.
Provides 
notification of changing utility power and UPS power conditions
  - User-replaceable 
  batteries
 
Increases 
availability by allowing a trained user to perform upgrades and replacements of 
the batteries reducing Mean Time to Repair (MTTR)
  - Disconnected 
  battery notification
 
Warns 
when a battery is not available to provide backup power.
  - Predicitive 
  failure notification
 
Provides 
early-warning fault analysis ensuring proactive component replacement.
Adaptability
Protects 
the initial investment in the UPS when migrating from tower to rack-mount 
environment.
  - Flash 
  upgradeable firmware
 
Install 
maintenance releases of firmware remotely using FTP.
  - Plug-and-Play 
  external batteries
 
Ensures 
clean, uninterrupted power to the loads when adding extra runtime to the 
UPS.
Manageability
Provides 
remote power management of the UPS over the network.
Quickly 
understand unit and power status with visual indicators.
  - InfraStruXure 
  Manager Compatible
 
Enables 
centralized management via the APC InfraStruXure Manager.
Provides 
management of the UPS via a serial port.
Customize 
UPS capabilities with management cards.
Manageability
Provides 
remote power management of the UPS over the network.
  - InfraStruXure 
  Manager Compatible
 
Enables 
centralized management via the APC InfraStruXure Manager.
Customize 
UPS capabilities with management cards.
Provides 
management of the UPS via a serial port.
Quickly 
understand unit and power status with visual indicators.
Marketing Features
  - Low 
  operating and maintenance costs with proven reliability and intelligent 
  battery management.
 
Intelligent 
battery management, pioneered by APC, maximizes battery performance and life 
through intelligent, precision temperature compensated charging. Automatic self 
tests insure battery reliability and warn customers in advance of battery 
replacement. Convenient, easy to connect, hot-swappable battery modules provide 
battery replacement without powering down.
  - Peace 
  of mind that comes with full equipment compatibility and reliability of a 
  leader
 
Provides 
pure sine wave output which is recommended by server manufacturers using active 
power factor corrected (PFC) power supplies. Safety agency tested and approved 
means that you can deploy Smart-UPS with confidence that they meet or exceed the 
industrys most rigorous standards.
  - Avoids 
  costly power problems by keeping your IT equipment and data protected and 
  available.
 
Network 
grade power conditioning protects from damaging surges and disruptive noise. The 
double conversion architecture provides tight voltage regulation, frequency 
regulation ,and zero transfer time to battery during power events.
  - Save 
  time with easy and convenient remote accessibility.
 
Network 
manageable via serial, USB or optional Ethernet. Includes Powerchute Network 
Shutdown Software for convenient monitoring and control, safe operating system 
shutdown, and innovative energy management capabilities.
Availability
Allows 
additional run time to be quickly added as needed.
  - Automatic 
  internal bypass
 
Supplies 
utility power to the connected loads in the event of a UPS power overload or 
fault.
  - Automatic 
  restart of loads after UPS shutdown
 
Automatically 
starts up the connected equipment upon the return of utility power.
  - Intelligent 
  battery management
 
Maximizes 
battery performance, life, and reliability through intelligent, precision 
charging.
  - Temperature-compensated 
  battery charging
 
Prolongs 
battery life by regulating the charge voltage according to battery 
temperature.
Ensures 
clean, uninterrupted power to protected equipment while batteries are being 
replaced
 
 
Specifications
Output
2.7 
KWatts / 3.0 kVA 
  - Max 
  Configurable Power (Watts)
 
2.7 
KWatts / 3.0 kVA 
230V 
Configurable 
for 220 : 230 or 240 nominal output voltage 
  - Output 
  Voltage Distortion
 
Less 
than 2% 
  - Output 
  Frequency (sync to mains)
 
50/60Hz 
+/- 3 Hz 
220, 
240 
3 
: 1 
Double 
Conversion Online 
Sine 
wave 
(8) 
IEC 320 C13 (Battery Backup) 
(2) 
IEC 320 C19 (Battery Backup) 
Internal 
Bypass (Automatic and Manual) 
Input
230V 
40 
- 70 Hz (auto sensing) 
British 
BS1363A, IEC-320 C20, Schuko CEE 7/EU1-16P 
2.44 
meters 
  - Input 
  voltage range for main operations
 
160 
- 275 V 
  - Input 
  voltage adjustable range for mains operation
 
100 
- 275 (half load) V 
3 
220, 
240 
Batteries 
& Runtime
Maintenance-free 
sealed Lead-Acid battery with suspended electrolyte : leakproof 
3 
hour(s) 
APCRBC152 
1 
1 
  - Battery 
  Volt-Amp-Hour Capacity
 
505 
APC-Smart-UPS-SRT-3000VA-230V 
View Runtime Graph 
View Runtime Chart 
View Efficiency Graph 
Communications 
& Management
RJ-45 
Serial , Smart-Slot , USB 
Multi-function 
LCD status and control console 
Audible 
and visible alarms prioritized by severity 
  - Emergency 
  Power Off (EPO)
 
Yes 
  - Available 
  SmartSlot Interface Quantity
 
1 
Surge 
Protection and Filtering
340 
Joules 
-- 
Physical
432 
, 43.2 cm 
85 
, 8.5 cm 
635 
, 63.5 cm 
31.3 
kg 
36.74 
kg 
246 
, 24.6 cm 
599 
, 59.9 cm 
871 
, 87.1 cm 
Black 
6.0 
Environmental
0 
- 40 C 
  - Operating 
  Relative Humidity
 
0 
- 95% no % 
0-3000 
meters 
-15 
- 45 C 
  - Storage 
  Relative Humidity
 
0 
- 95% no % 
0-15000 
meters 
  - Audible 
  noise at 1 meter from surface of unit
 
55.0 
dBA 
  - Online 
  thermal dissipation
 
703.0 
BTU/hr 
IP 
20 
Conformance
CE, 
CE Mark, EAC, EN/IEC 62040-1, EN/IEC 62040-2, ENERGY STAR (EU), RCM, VDE 
3 
years repair or replace (excluding battery) and 2 years for battery